Power derating curve

(1)Rated power:
Standard ambient temperature is 30℃. If ambient temp. is over 30℃,
calculate the max power by multiplying rated power with the designated ratio from the derating curve.
(2) Rated power:
E=  √R×P
E:rated voltage(V)
P:rated power(W)
R:Rated resistance(Ohms)
The rated voltage is the corresponding voltage of
DC or AC (impedance of the commercially used frequency) based on the formula above.

Derating curve (RG, RM series)

Derating curve

RRseries
RTseries
RL0510 0816 1220 3720 3720W

Derating curve(RL7520W)

Rated current

The current that causes 20℃ temperature increase by impedance.
If the ambient temperature exceeds 70℃, reduce the current according to the derating curve below.
Power=(current)2 x DC Resistance of the product

Derating curve

HPL0603 0510