| (1) Rated power: |
Standard ambient temperature is 30°C. If ambient temp. is over 30°C, calculate the max power by multiplying rated power with the designated ratio from the derating curve. |
| |
|
| (2) Rated power: |
E= √R*P |
| |
E: rated voltage(V), P: rated power (W), R: Rated resistance (Ohms). |
| |
The rated voltage is the corresponding voltage of DC or AC (impedance of the commercially used frequency) based on the formula above. |
■Derating curve (RG, RM series)

■Derating curve
RRseries RTseries RL0510 0816 1220 3720 3720W

■Derating curve(RL7520W)

Rated current
The current that causes 20°C temperature increase by impedance. If the ambient temperature exceeds 70°C, reduce the current according to the derating curve below. Power=(current)2 x DC Resistance of the product
■Derating curve
TFL0510 0816 HPL0603 0510
|